With the extensive line of standard Multifan Panel Fans, we offer a wide range of reliable and efficient fans. These robust fans are used for various agricultural applications like greenhouses, pork-, dairy- and poultry barns and several industrial applications like factories and buildings. These fans are engineered for continuous operation in highly corrosive environments and are suitable for outdoor use. Multifan Panel Fans are optional available with the energy efficient ECplus technology.
- Materials resistant to extreme corrosive environments
- Extreme durable fan with a long lifetime
- Easy installation and maintenance
- High performances and energy efficient
- 3-year warranty
- Standard suitable for ambient temperatures up to 40 ˚C
- Water and dust resistant fan motor (IP55)
- Various motor and impeller types
- Low noise level
- Wire guards in accordance with CE-standard
- ECplus technology for more efficiency
- Override switch for ECplus technology
- Agricultural: Pig, Poultry and Dairy
- Horticulture: Greenhouse
- Industry: Cooling, Heating and Ventilation
With the ECplus technology we combine excellent performance and robust quality with high energy savings up to 80% (IFIP, 2015). The ECplus controller enables a smooth and precise ventilation system. We know the reliablity of the fan is for most of our customers a key aspect. With the optional override switch the fan can be switched manually to 100% ventilation in case of emergency.
Please, contact your dealer or our Polnet Customer Service Team for more options or more technical details.
ø [cm] | RPM | Pin at 0 Pa [W] | SFP at 0 Pa [W/1000 m3/h] | I1 at 0 Pa (Δ) [A] | I2 at 0 Pa (Y) [A] | I1 max (Δ) [A] | I2 max (Δ) [A] | Qv (m3/h) | Contollability* | LPA** dB [A] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0 Pa | 30 Pa | 50 Pa | 80 Pa | 100 Pa | 150 Pa | ||||||||||
20 | 1400 | 60 | 92,3 | 0,5 | - | 0,5 | - | 650 | - | - | - | - | - | E/T | 43 |
25 | 1370 | 100 | 83,3 | 0,7 | - | 0,7 | - | 1.200 | - | - | - | - | - | E/T | 45 |
30 | 2750 | 360 | 97,3 | 1,6 | - | 1,7 | - | 3.700 | 3.450 | 3.350 | 3.100 | 2.950 | 2.450 | E/T | 61 |
30 | 1400 | 100 | 42,6 | 0,5 | - | 0,6 | - | 2.300 | 2.050 | 1.700 | - | - | - | E/T | 44 |
35 | 1400 | 150 | 42,9 | 0,8 | - | 0,9 | - | 3.500 | 3.100 | 2.850 | - | - | - | E/T | 47 |
40 | 1405 | 230 | 47,4 | 1,2 | - | 1,3 | - | 4.850 | 4.400 | 4.100 | 3.400 | - | - | E/T | 50 |
45 | 1400 | 300 | 47,2 | 1,4 | - | 1,6 | - | 6.350 | 5.850 | 5.400 | 4.550 | - | - | E/T | 52 |
50 | 1400 | 450 | 53,6 | 1,9 | - | 2,1 | - | 8.400 | 7.750 | 7.250 | 6.350 | 5.550 | - | E/T | 55 |
50 | 1400 | 580 | 59,5 | 2,7 | - | 4 | - | 9.750 | 9.200 | 8.750 | 8.060 | 7.500 | - | E/T | 59 |
56 | 950 | 430 | 46,4 | 1,9 | - | 2,1 | - | 9.200 | 8.390 | 7.750 | 6.900 | - | - | E/T | 55 |
63 | 910 | 560 | 45,5 | 2,5 | - | 2,7 | - | 12.300 | 11.300 | 10.400 | 8.700 | - | - | E/T | 55 |
71 | 910 | 590 | 43,3 | 2,8 | - | 3,5 | - | 13.600 | 12.250 | 11.300 | 9.700 | - | - | E/T | 60 |
92 | 920 | 750 | 35,7 | 3,3 | - | 3,8 | - | 21.000 | 18.600 | 16.800 | 13.900 | - | - | E/T | 61 |
92 | 935 | 650 | 36,1 | 2,9 | - | 3,8 | - | 18.000 | 16.300 | 14.600 | 11.900 | - | - | E/T | 61 |
* E = Electronically controllable (electronic voltage control by TRIAC), T = Trafo controllable (voltage control by transformer), F = Frequency controllable by frequency controller. A frequency controller in combination with a single-phase motor is possible.
** Sound pressure level measured at 7 meter, free blowing distance. All motors meet the IP55 standard.
*** Data according ErP (Energy related Products)-directives (EU Commission Regulation 327/2011). Measurements without wireguard.
ø [cm] | RPM | Pin at 0 Pa [W] | SFP at 0 Pa [W/1000 m3/h] | I1 at 0 Pa (Δ) [A] | I2 at 0 Pa (Y) [A] | I1 max (Δ) [A] | I2 max (Δ) [A] | Qv (m3/h) | Contollability* | LPA** dB [A] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0 Pa | 30 Pa | 50 Pa | 80 Pa | 100 Pa | 150 Pa | ||||||||||
30 | 2750 | 330 | 89,2 | 1,2 | 0,7 | 1,3 | 0,7 | 3.700 | 3.550 | 3.400 | 3.200 | 3.050 | 2500 | T/F | 62 |
30 | 1450 | 90 | 39,1 | 0,5 | 0,3 | 0,5 | 0,3 | 2.300 | 2.000 | 1.700 | - | - | - | T/F | 44 |
35 | 1450 | 160 | 45,7 | 0,9 | 0,5 | 0,9 | 0,5 | 3.500 | 3.150 | 2.900 | - | - | - | T/F | 47 |
40 | 1400 | 210 | 43,3 | 1 | 0,6 | 1 | 0,6 | 4.850 | 4.400 | 4.050 | 3.350 | - | - | T/F | 50 |
45 | 1350 | 290 | 45,3 | 1,2 | 0,7 | 1,2 | 0,7 | 6.400 | 5.850 | 5.400 | 4.500 | - | - | T/F | 52 |
50 | 1400 | 380 | 45,5 | 1,8 | 1,1 | 1,9 | 1,1 | 8.350 | 7.700 | 7.150 | 6.300 | 5.450 | - | T/F | 55 |
56 | 1455 | 950 | 70,1 | 3,6 | 2,1 | 3,8 | 2,2 | 13.550 | 13.000 | 12.000 | 11.300 | 10.800 | - | T/F | 61 |
63 | 1360 | 1100 | 69,2 | 3,9 | 2,3 | 4,2 | 2,4 | 15.900 | 15.200 | 14.700 | 13.800 | 13.400 | 11.700 | T/F | 63 |
63 | 1460 | 1400 | 77,1 | 5,2 | 3 | 5,5 | 3,2 | 17.900 | 17.100 | 16.600 | 15.900 | 15.300 | 13.900 | F | - |
71 | 1435 | 1150 | 65,7 | 3,9 | 2,2 | 4,3 | 2,5 | 17.500 | 16.800 | 16.300 | 15.300 | 15.000 | 13.300 | F | 64 |
71 | 1450 | 1650 | 76,3 | 5,6 | 3,3 | 6 | 3,5 | 21.400 | 20.600 | 20.000 | 18.900 | 18.200 | 16.500 | F | - |
50 | 930 | 220 | 35,2 | 1 | 0,6 | 1,2 | 0,7 | 6.250 | 5.500 | 4.650 | - | - | - | T/F | 50 |
56 | 890 | 290 | 34,5 | 1,1 | 0,6 | 1,3 | 0,7 | 8.450 | 7.400 | 6.500 | - | - | - | T/F | 49 |
63 | 905 | 560 | 46,1 | 2,1 | 1,2 | 2,5 | 1,5 | 12.200 | 11.100 | 10.300 | 8.700 | - | - | T/F | 54 |
71 | 895 | 760 | 53,9 | 2,6 | 1,5 | 2,7 | 1,6 | 15.700 | 14.300 | 13.300 | 11.500 | - | T/F | 56 | 55 |
92 | 895 | 670 | 32,9 | 2,4 | 1,4 | 2,7 | 1,5 | 20.400 | 18.100 | 16.200 | 13.200 | - | - | T/F | 61 |
92 | 905 | 1050 | 42,5 | 4,1 | 2,4 | 5 | 2,9 | 24.500 | 22.600 | 20.500 | 17.300 | 14.300 | - | T/F | 63 |
* E = Electronically controllable (electronic voltage control by TRIAC), T = Trafo controllable (voltage control by transformer), F = Frequency controllable by frequency controller. A frequency controller in combination with a single-phase motor is possible.
** Sound pressure level measured at 7 meter, free blowing distance. All motors meet the IP55 standard.
*** Data according ErP (Energy related Products)-directives (EU Commission Regulation 327/2011). Measurements without wireguard.
Figure | A01 | A02 | A03 | A04 | A05 | A06 | A07 | A08 | A09 | A10 | Weight [kg] | Packaging [LxWxH] |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 200 | 276 | 276 | 250 | 250 | 139 | 216 | 51 | 8 | 9 | 3,3 | 280 x 280 x 190 |
1 | 250 | 326 | 326 | 300 | 300 | 149 | 266 | 51 | 8 | 9 | 4,1 | 330 x 330 x 190 |
2 | 312 | 443 | 443 | 395 | 395 | 192 | 340 | 84 | 36 | 8 | 9 | 450 x 450 x 289 |
2 | 312 | 443 | 443 | 395 | 395 | 192 | 340 | 84 | 36 | 8 | 8,9 | 450 x 450 x 289 |
2 | 362 | 493 | 493 | 445 | 445 | 192 | 390 | 84 | 36 | 8 | 8,5 | 500 x 500 x 289 |
2 | 415 | 543 | 543 | 495 | 495 | 192 | 440 | 84 | 36 | 8 | 8,8 | 550 x 550 x 289 |
2 | 460 | 593 | 593 | 545 | 545 | 192 | 490 | 84 | 36 | 8 | 10,6 | 600 x 600 x 289 |
2 | 512 | 648 | 648 | 600 | 600 | 192 | 540 | 84 | 36 | 8 | 12,8 | 654 x 654 x 289 |
2 | 512 | 648 | 648 | 600 | 600 | 247 | 540 | 84 | 36 | 8 | 21,5 | 654 x 654 x 289 |
2 | 574 | 700 | 700 | 640 | 640 | 247 | 600 | 105 | 40 | 10 | 21,5 | 705 x 705 x 370 |
2 | 646 | 775 | 775 | 715 | 715 | 247 | 670 | 105 | 40 | 10 | 21,1 | 780 x 780 x 353 |
2 | 712 | 850 | 850 | 790 | 790 | 247 | 740 | 105 | 40 | 10 | 21,2 | 855 x 855 x 353 |
2 | 915 | 1005 | 1005 | 947 | 947 | 247 | 940 | 93 | 40 | 10 | 24 | - |
2 | 915 | 1005 | 1005 | 947 | 947 | 247 | 940 | 93 | 40 | 10 | 24 | - |
2 | 312 | 443 | 443 | 395 | 395 | 192 | 340 | 84 | 36 | 8 | 10 | 450 x 450 x 289 |
2 | 312 | 443 | 443 | 395 | 395 | 192 | 340 | 84 | 36 | 8 | 8,8 | 450 x 450 x 289 |
2 | 362 | 493 | 493 | 445 | 445 | 192 | 390 | 84 | 36 | 8 | 9,6 | 500 x 500 x 289 |
2 | 415 | 543 | 543 | 495 | 495 | 192 | 440 | 84 | 36 | 8 | 8,5 | 450 x 450 x 289 |
2 | 460 | 593 | 593 | 545 | 545 | 192 | 490 | 84 | 36 | 8 | 11,5 | 600 x 600 x 289 |
2 | 512 | 648 | 648 | 600 | 600 | 192 | 540 | 84 | 36 | 8 | 10,7 | 654 x 654 x 289 |
2 | 574 | 700 | 700 | 640 | 640 | 247 | 600 | 105 | 40 | 10 | 18,4 | 705 x 705 x 370 |
2 | 646 | 775 | 775 | 715 | 715 | 247 | 670 | 105 | 40 | 10 | 21,6 | 780 x 780 x 353 |
2 | 646 | 775 | 775 | 715 | 715 | 247 | 670 | 105 | 40 | 10 | 23,7 | 780 x 780 x 353 |
2 | 712 | 850 | 850 | 790 | 790 | 247 | 740 | 105 | 40 | 10 | 23,6 | 855 x 855 x 353 |
2 | 512 | 648 | 648 | 600 | 600 | 192 | 540 | 84 | 36 | 8 | 13 | 654 x 654 x 289 |
2 | 574 | 700 | 700 | 640 | 640 | 247 | 600 | 105 | 40 | 10 | 14,8 | 705 x 705 x 370 |
2 | 646 | 775 | 775 | 715 | 715 | 247 | 670 | 105 | 40 | 10 | 20 | 780 x 780 x 353 |
2 | 712 | 850 | 850 | 790 | 790 | 247 | 740 | 105 | 40 | 10 | 21,3 | 855 x 855 x 353 |
2 | 915 | 1005 | 1005 | 947 | 947 | 247 | 940 | 93 | 40 | 10 | 25 | - |
2 | 915 | 1005 | 1005 | 947 | 947 | 247 | 940 | 93 | 40 | 10 | 24,1 | - |